NOTE:
In this test, an idle time of approximately 2 minutes needs to be observed and
the hand pump needs to be reloaded to operating pressure.
The resulting max. operating pressure must not drop by more than 5% after
10 seconds.
A test pressure gauge is available from the LUKAS line of accessories.
Perform an operational check of the hand pump at least once a year; in the case of continuous
use, once every half year.
Operational check
no suspicious noises,
tests at maximum load.
Execution:
Place the hand pump on a solid base to operate. Then, connect a test manometer to the
supply hose line. Release the pump lever lock and close the discharge valve. Then, the
pressurisation to operating pressure corresponding to the specication on the identication
plate occurs.
10.3 Changingortoppingupthehydraulicuid
The hydraulic uid should be changed if dirty at least once a year. When the hand pump is
operated in an especially dusty environment, we recommend changing the uid at least once
every six months.
ATTENTION!
Add hydraulic uid only if the hand pump is disconnected from the lines or the
equipment operated with the pump is hydraulically depressurised. Otherwise,
after lling the entire hydraulic system could contain more hydraulic uid than
the tank can hold.
Procedure:
1. Open the bleed/ll cap on the tank.
2. Add hydraulic uid until the uid level comes up to 1-2 cm below the top edge of the oil
tank.
3. Bleed the hand pump as described in the chapter "bleeding the pump".
4. Check the uid level again and close the tank again at the correct uid level with the
vent/ll cap on the tank. Should the tank no longer be sufciently full after bleeding, start
the ll procedure again at item 2.
NOTE:
Should the uid level in the tank still not be reached after repeated relling (during
maintenance), we recommend searching for leaks in the hydraulic system.
10.4 Care
If possible, do not store the hand pump in a damp or extremely dusty environment in order
to ensure a long service life. If this is unavoidable, you should perform more frequent
maintenance and/or shield the pump from these effects if possible.