NOTE:
In this test, an idle time of approximately 2 minutes needs to be observed and
the hand pump needs to be reloaded to operating pressure.
The resulting max. operating pressure must not drop by more than 5% after
10 seconds.
A test pressure gauge is available from the LUKAS line of accessories.
Perform an operational check of the hand pump at least once a year; in the case of continuous
use, once every half year.
Operational check
• no suspicious noises,
• tests at maximum load.
Execution:
Place the hand pump on a solid base to operate. Then, connect a test manometer to the
supply hose line. Release the pump lever lock and close the discharge valve. Then, the
pressurisation to operating pressure corresponding to the specication on the identication
plate occurs.
10.3 Changingortoppingupthehydraulicuid
The hydraulic uid should be changed if dirty at least once a year. When the hand pump is
operated in an especially dusty environment, we recommend changing the uid at least once
every six months.
ATTENTION!
Add hydraulic uid only if the hand pump is disconnected from the lines or the
equipment operated with the pump is hydraulically depressurised. Otherwise,
after lling the entire hydraulic system could contain more hydraulic uid than
the tank can hold.
Procedure:
1. Open the bleed/ll cap on the tank.
2. Add hydraulic uid until the uid level comes up to 1-2 cm below the top edge of the oil
tank.
3. Bleed the hand pump as described in the chapter "bleeding the pump".
4. Check the uid level again and close the tank again at the correct uid level with the
vent/ll cap on the tank. Should the tank no longer be sufciently full after bleeding, start
the ll procedure again at item 2.
NOTE:
Should the uid level in the tank still not be reached after repeated relling (during
maintenance), we recommend searching for leaks in the hydraulic system.
10.4 Care
If possible, do not store the hand pump in a damp or extremely dusty environment in order
to ensure a long service life. If this is unavoidable, you should perform more frequent
maintenance and/or shield the pump from these effects if possible.
Regularly coat all metal parts with oil to prevent any corrosion.