Operating instructions for rescue equipment172080085 GBeDRAULIC equipment(Translation of the original operating instructions)replaces 01.2012(Cutter,
104. Functional description 4.1 DescriptionThe cutters and combi tools have been designed in such a way that a hydraulically operated piston activates
11 4.2 Structure of the rescue equipment4.2.1 Cutter2 1 Star grip 2 Main switch 3 Quick exchange battery or power supply 4 Release button for
124.2.3 Spreader2345678101 1 Star grip 2 Main switch 3 Quick exchange battery or power supply 4 Release button for Battery and power supply 5 H
134.2.4 Rescue ram 1 Star grip 2 Main switch 3 Quick exchange battery or power supply 4 Release button for Battery and power supply 5 Ventilati
14 4.4 Controlling the operating movements The piston movement is controlled by the star grip on the attached valve (see illustration below).Star gr
15 5.2 Operating the star grip (also see chapter on "Controlling the operating movements")Open the device or extend the piston (
16It is strictly prohibited to reach into the path of the rescue device (e.g. between the blades or spreader arms or between the rescue ram and the ma
17During cutting, the gap between the blade tips (in the transverse direction) must not be exceeded, otherwise the blade is in danger of breaking:ATTE
18Working surface is too small, tips slip off.Only for increasing the size of a gap (not suitable for spreading)Tips get a safe grip. Work with the ti
19AThe connection pieces for the LUKAS chain sets are attached to the boreholes A on the blades using load bolts.(see fi gure on the right).Chain sets:
2 Contents Page 1. Danger classes 4 2. Product safety 5 3. Intended Use 8 4. Functional description 10 4.1 Description 10 4.2 Structure of the
20 6.6 Squashing (rescue ram)Before you can carry out any work with the rescue ram, you must ensure adequate support. This also includes any necessary
217. Dismantling the equipment / deactivation following operationOnce work has been completed, the arms should be closed until the tips are only a few
22Inspections to be carried out:Visual inspectionCutter and combi tool• Opening width of the blade arms on the tips (see chapter "Technical data
23 9.1 General information 9. RepairsServicing may only be carried out by the manufacturer or personnel trained by the manufacturer and by authorised
24 9.2 Preventive maintenance 9.2.1 Care instructionsFrom time to time, the outside of the device should be cleaned with a damp cloth (not the electri
25ABBCCDWork steps:1. First of all, carefully clean the rescue equipment.2. Remove the fi xing screws "A" and remove the protective cover &qu
26HJKLONPMONM4. First remove the grub screw "G", then the central bolt nut "H" and then pull out the central pin "J". 5.
279.3.2 Changing the blades, protective cover and handle on the S311E cutter and on the SC350E and SC250E combi toolsComponents to be replacedRequire
28HJHJKMMLDG5. Remove self-locking nut D and push the pivot bolt G out.6. Remove the retaining rings H and push out bolt J.7. Now, you can remove bla
2910. The work steps must be carried out in reverse order to fi t the new parts.ATTENTION!Don’t forget to apply LUKAS special grease to all sliding su
3 11. Technical data 38 11.1 eDRAULIC cutter 38 11.2 eDRAULIC combi tool 39 11.3 eDRAULIC spreader 40 11.4 eDRAULIC rescue ram 41 11.5 Noise
30ATTENTION!If you have not maintained the smoothness or incline, the proper operation of the blade is no longer guaranteed and the blades must be rep
31Work steps:1. First of all, carefully clean the rescue equipment. Now switch off the device and remove the battery or unplug the power supply from t
324. Remove the two two-piece locking elements "E" on the protective cover "F" and remove the two-piece protective cover by pullin
33KLKLHLKLKK7. Also remove the retaining rings "M" and remove the pins "N". You can then remove the spreader arms "H".HM
34NOTE:The torque required can be taken from the spare parts list of your particular unit.ATTENTION!Don’t forget to apply LUKAS special grease to all
359.3.6 LabelsAll damaged and/or illegible labels (safety instructions, type plate, etc.) must be renewed.Procedure:1. Remove damaged and/or illegible
3610. TroubleshootingTrouble Control Cause SolutionBlades, spreader arms or cylinder pistons move slowly or jerkily when operatedBattery fully charged
37If you cannot rectify the malfunctions, inform an authorised LUKAS dealer or the LUKAS customer service department immediately!The address of the LU
3811. Technical data 11.1 eDRAULIC cutterType S 311 E S 700 ERef.no. 90-20-20 (172090000) 90-20-70 (172080000)Dimensions (without battery)l x w x h[m
39 11.2 eDRAULIC combi tool Type SC 250 E SC 350 ERef.no.90-30-10(173000000, 173115000)90-30-20 (173010000)Dimensions (excl. battery)l x w x h[mm] 87
4 Wear a helmet with a face guard Wear protective gloves Wear safety shoes Proper recycling Observe principles of environmental protection Read
40 11.3 eDRAULIC spreaderType SP 300 ERef.no. 90-10-15 (171050000)Dimensions (excl. battery)l x w x h[mm] 895 x 355 x 290[in.] 35.2 x 14.0 x 11.4Maxi
41 11.4 eDRAULIC rescue ram 11.5 Noise emissions (based on the EN ISO 3744 standard)Type R 411 ERef.no. 90-40-10 (174080000)Length(retracted)[mm] 54
42 11.6 Operating and storage temperature rangesOperating temperature [°C] / [°F] -20 … +55 -4 … +131Ambient temperature (device in operation)[°C] /
4312. EC Declarations of conformity
4513. Accessories 13.1 BatteriesOnly LUKAS lithium-ion rechargeable batteries may be used to operate eDRAULIC tools. These guarantee optimum performa
46 13.3 Power supplyThe eDRAULIC devices have a unique power supply with integrated electronics, allowing the devices to be operated for an almost u
4714. Instructions regarding disposalElectrical equipment, accessories and packaging should always be disposed of in an environmentally compatible way
4815. Notes
49
52. Product safetyLUKAS products are developed and manufactured to guarantee the best performance and quality when used properly.Operator safety is th
LUKAS Hydraulik GmbHA unit of the IDEX CorporationWeinstraße 39, Erlangen, 91058 GermanyTel.: (+49) 0 91 31 / 698 - 0Fax.: (+49) 0 91 31 / 698 - 3
6In the event of malfunctions, shut down the device immediately and make it safe. Repair the fault immediately.Do not carry out any changes (additions
7Protect the eDRAULIC devices against humidity and moistureThe eDRAULIC devices are not suitable for underwater use.The equipment is fi lled with hydra
83. Intended UseLUKAS eDRAULIC devices have been specially designed to rescue or retrieve the bodies of victims of road, rail or aircraft accidents or
9You can order spare parts and accessories for the rescue tools from your authorised LUKAS dealer!Applications: